DC-DC Converters |
Heavy Duty 110VDC input Battery
Charger
|
Heavy Duty 250VDC input Battery
Charger
|
Heavy Duty 300VDC input Battery
Charger
|
Part Number and Price |
PBCD310-110-24 $762 Allow up to 14 days for manufacturing |
PBCD310-250-24
$1012 Allow up to 14 days for manufacturing |
PBCD310-300-24
$1012 Allow up to 14 days for manufacturing |
Country of Origin |
Canada, NAFTA
eligible |
Canada, NAFTA
eligible |
Canada, NAFTA
eligible |
Nominal Input Voltage |
110VDC |
250VDC |
300VDC |
Input Voltage Range |
100VDC to
140VDC |
230VDC to
280VDC |
280VDC -
360VDC |
Absorption Voltage |
28.8V |
Float Voltage |
27.2VDC |
Output Voltage Adjustment |
±1V typical |
Max Output Current(s) |
10
Amps |
Transition current |
1.5
Amps |
Duty Cycle |
100%
rated power 24 hours a day |
Reverse Polarity Protection? |
Yes |
Current Limiting? |
Yes |
Yes |
Yes |
Over Temperature shutdown? |
Yes |
Yes |
Yes |
Short Circuit Protection? |
Yes |
Yes |
Yes |
Stages |
2 or 3
user selectable |
Input Under voltage Shutdown? |
Yes |
Output Overvoltage Crowbar? |
Yes |
Output Crowbar Trigger
Voltage |
16V
±0.5V |
|
|
Dry Contact Output Fail
Relay? |
Yes |
Yes |
Yes |
Can be left Permanently
Attached? |
Yes |
Yes |
Yes |
Temperature Compensated
Charging? |
Yes |
Yes |
Yes |
Temperature Compensation
Schedule |
-30mV/°C |
-30mV/°C |
-30mV/°C |
Operating Temperature Range |
-25°C to
+40°C |
-25°C to
+40°C |
-25°C to
+40°C |
Operating Temperature Range with
Derating |
-25°C to
+50°C |
-25°C to
+50°C |
-25°C to
+50°C |
Derating |
2.5% per °C up
to +50°C |
2.5% per °C up
to +50°C |
2.5% per °C up
to +50°C |
Efficiency |
>75 % |
>75 % |
>75 % |
Line Regulation |
<±0.5% |
<±0.5% |
<±0.5% |
Load Regulation |
<±0.5% |
<±0.5% |
<±0.5% |
Transient Response |
<2V for 50%
surge |
<2V for 50%
surge |
<2V for 50%
surge |
Switching frequency |
60 kHz |
60 kHz |
60 kHz |
Output ripple noise |
<25 mV rms |
<25 mV rms |
<50 mV rms |
Isolation |
Fully
isolated: >1500 volts isolation from case to any input terminal,
>500V isolation between case and any output terminal, >1500 Volts
isolation input to output. Transient voltage suppression. |
Indicators |
Audio
and visual indicators for constant current, low input voltage, low output
voltage, over temperature. Dry Contact output failure relay. |
Input Fuse |
5A MDA |
3A MDA |
10A MDA |
Output Fuse |
10A AGC |
10A AGC |
20 x 2 ATC |
Input Connection |
cable |
cable |
cable |
Connections |
4 contact screw
terminal |
4 contact screw
terminal |
4 contact screw
terminal |
Protection |
Over Voltage , Over Current, Short Circuit , Reverse
Polarity , Over Load |
Dimensions |
244
x 208 x 64 mm (9.6 x 8.2 x 3.5 inches) |
244
x 208 x 64 mm (9.6 x 8.2 x 3.5 inches) |
368
x 251 x 76 mm (14.5 x 9.9 x 3 inches) |
Drawings |
Click Here for Drawing |
Weight |
3.4
Kg (7.5 lbs) |
3.4
Kg (7.5 lbs) |
3.3
Kg (7.2 lbs) |
Audible Noise |
None |
None |
None |
Typical service life |
87000 hours |
87000 hours |
87000 hours |
Warranty |
3 years |
3 years |
3 years |
Approvals |
Built