These IP67 rated DC-DC
converters are not hermetically sealed, but they are fully IP676 ingress
protected, including immersion. They have a wide operating temperature range,
and use a single military style circular bayonet connector which contains both
input and output terminals. The wide input voltage range allows use in 12V or
24V systems, and designed to allow the use of 36 volt equipment in 12 volt, 14
volt, and 24 volt vehicles, marine, military, boat, yacht, PLC, and cell tower
applications. These are attractive, reliable, robust DC/DC converters good for
fork lifts, off-road, construction and recreational equipment. They are
relatively immune to vibration and shock.
To determine the output amps
you need just add up the watts of all the equipment and divide by 36V.
These converters are fully isolated and can be used for all 12 volt and
24 volt systems, including negative ground, positive ground, and floating
ground installations.
36V DC-DC
Converters |
15 Amp DC to
DC Converter
|
8 amp DC to
DC converter
|
Part Number and Price |
PSEC-738HS Replaces the PSEC-737HS $1200 |
PSEC-638HS Replaces the PSEC-637HS $938 |
Cable with connector |
Cable and connector PSEC-68-0749-6 $295 each |
The cable and all parameters are the same except where listed
below |
Connector only |
CA3106E24-11SB NATO connector without cable $110
each One cable is used
|
|
Nominal Input Voltage |
12VDC and 24VDC |
|
Input Voltage range |
10.5 to 32VDC |
|
Max Input current at No Load |
<220 mA |
<150 mA |
Output voltage |
36V |
36V |
Output voltage adjustment by
removing the front plage |
32 VDC to 42 VDC |
|
Max Output Current(s) |
20 Amps for output voltages set between 32V and 42V |
10A for output voltages adjusted to 32V and 42V |
Max Output Power; the actual
output current depends on the ratio between the input and output voltages. |
Maximum Output power = Vout * 20 amps For example 42 volts *
20 Amps = 840 Watts |
Vout*10 amps |
Max Output Power
(continuous) |
850W |
450W |
Output current limit? |
110% of maximum current with continuous automatic retry, 1000W peak
for short pulses |
Short pulses up to 550W |
Operating Temperature Range at
100% load |
-40°C to +70°C |
|
Operating humidity |
0-100% |
|
Efficiency |
>92 % at 50% rated power >88% at full rated power |
|
Load Regulation |
<250mV with remote sensing |
|
Maximum input current |
71A at 11.5Vin, 25.5Vout |
36A at 11.5V in, 26V out |
Switching frequency |
kHz |
|
Output ripple noise |
<50 mV rms |
|
Isolation |
Fully isolated between input and output 2500VAC rms Housing to
input >1800VAC Housing to output >1800VAC |
|
Remote power on/off |
Yes, through grounding a wire on the connector |
|
Remote voltage sense |
Yes. through two sense wires on the connector |
|
Ingress rating |
IP676, (dust tight, immersion up to 1 meter depth, 1 Joule
mechanical impact energy) |
|
Connections |
Mating connector is the Canon 3106E24 - 11SB. See the connection
diagram below |
|
Protection |
Low input voltage < 10.5 +/-0.3 VDC, High input voltage >
32.0 +/- 1.0 VDC Over temperature by internal thermostat, self
resetting |
|
Cooling |
Through convection and the baseplate |
|
Dimensions |
14.62 x 7.75 x 2.95 inches 37 x 20 x 7.5 cm |
8.62 x 7.75 x 2.95 inches 21.9 x 20 x 7.5 |
Fuse can be accessed by removing
the front cover |
ATC-30 |
|
Drawings |
See below |
|
Weight |
5.5 kg (12 lbs) |
3.2 kg (7 lbs) |
Audible Noise |
None |
|
Warranty |
2
years limited warranty for parts and labor |
|
PSEC-738HS drawing:
PSEC-638HS drawing:
Heavy Duty, High Current Switchmode 12VDC/ 36VDC Converters.
Wide input voltage range suitable for 12 Volt, 24 Volt and 28 Volt
systems. |