AC-DC Converters |
7.5 Amps 36 Volt
|
15 Amp 36 Volt
|
30 Amp 36 Volt
|
37 Amp 36 Volt
|
Part Number |
PWS310-110-36 PWS310-220-36 |
PWS610-110-36 PWS610-220-36 |
PWS1000-110-36 PWS1000-220-36 |
PWS1505-110-36 PWS1505-220-36 |
Input Voltage |
90-130VAC 45-65 Hz also 210-250VAC version |
90-130VAC 45-65 Hz also 180-260VAC version |
90-130VAC 45-65 Hz also 180-260VAC version |
90-130VAC 45-65 Hz also 180-260VAC Field Convertible to
220VAC or back to 110VAC |
Output Voltage |
36 VDC |
36 VDC |
36 VDC |
36 VDC |
User Adjustable output voltage? |
Yes |
Yes |
Yes |
Yes |
Max Output Current(s) |
10 Amps peak 10 minutes maximum |
20 Amps Peak 10 minutes maximum |
41 Amps Peak |
51 Amps Peak |
Max Output Power (Peak) |
360 Watts (10 Amps @ 36V) |
720 Watts (20 Amps @ 36V) |
1476 Watts (36 Amps at 36V) |
1836 Watts (51A @ 36V) |
Continuous Amperage |
7.6A |
15A |
30A |
38A |
Max Output Power (continuous) |
270 Watts (7.5 Amps @ 36V) |
540 Watts (15 Amps @ 36V) |
1080 Watts (30 Amps @ 36V) |
1332 Watts (37 Amps @ 36V) |
Duty Cycle |
7.5 Amps for 24 hours per day |
15 Amps for 24 hours per day |
30 Amps for 24 hours per day |
37 Amps for 24 hours per day |
Output current limiting for use in battery charging? |
Yes |
Yes |
Yes |
Yes |
Operating Temperature Range |
-25°C to +40°C |
-25°C to +40°C |
-25°C to +40°C |
-25°C to +40°C |
Derating |
2.5% per °C from +40°C |
2.5% per °C from +40°C |
2.5% per °C from +40°C |
2.5% per °C from +40°C |
Efficiency at full power |
>80 % |
>80 % |
>80 % |
>85 % |
Line Regulation |
<±0.5% |
<±0.5% |
<±0.5% |
<±0.5% |
Load Regulation |
<±0.5% |
<±0.5% |
<±0.5% |
<±0.5% |
Switching frequency |
kHz |
kHz |
kHz |
kHz |
Output ripple noise |
<25 mV rms |
<50 mV rms |
<50 mV rms |
|
Isolation |
>1500 volts isolation from case to input, and between input and
output <500 volts case-output |
>1500 volts isolation from case to input, and between input and
output >500 volts case-output |
>1500 volts isolation from case to input, and between input and
output >500 volts case-output |
>1500 volts isolation from case to input, and between input and
output >500 volts case-output |
Remote power on/off |
option |
option |
option |
No |
Input Circuit Breaker |
7A / 4A for 220VAC |
15A / 8A for 220VAC |
25A fuse / 15A for 220VAC |
25A Breaker |
Connections |
Screw terminals for wire connection |
Screw terminals |
4 Screw Barrier Block Output Terminals |
Flying wire leads |
Protection |
Audible & visual indicators for output overload, low input
voltage, low output voltage & over-temperature |
Audible & visual indicators for
output overload, low input voltage, low output voltage &
over-temperature |
Audible & visual indicators for
output overload, low input voltage, low output voltage &
over-temperature |
Audible & visual indicators for
output overload, low input voltage, low output voltage &
over-temperature |
Dry contact relay on output failure |
Yes |
Yes |
Yes |
Yes |
Dimensions |
244 x 208 x 64 mm 9.6 x
8.2 x 3.5 inches) |
343 x 484 x 138 mm (13.5
x 19 x 3.5 inches) |
368 x 251 x 140 mm (14.5
x 9.9 x 5.5 inches) |
432 x 208 x 89 mm (17 x
8.2 x 3.5 inches) |
Drawings |
Click Here for Drawing |
Drawing |
Drawing |
Drawing |
Weight |
7.5 lbs |
14 lbs |
14 lbs |
15 lbs |
Audible Noise |
None |
None |
None |
Fan whisper |
Cooling |
Convection, no fan |
Convection, no fan |
Convection, no fan |
Thermostatically controlled fan |
Warranty |
3 years |
3 years |
3 years |
3 years |