DC-DC Converters |
Heavy Duty 10Amp 24V
110VAC Battery Charger
|
Heavy Duty 10 Amp 24V
220VAC Battery Charger |
Heavy Duty 22Amp 24V
110VAC Battery Charger
|
Heavy Duty 22 Amp 24V
220VAC Battery Charger
|
Heavy Duty 40 Amp 24V
110VAC Battery Charger
|
Heavy Duty 40 Amp 24V
220VAC Battery Charger
|
Heavy Duty 50 Amp 24V
110VAC Battery Charger
|
Part Number and Price |
PBCA310-110-24 $844
Allow up to 15 days for manufacturing |
PBCA310-220-24 $844 Allow up to 15 days for manufacturing |
PBCA610-110-24 $1102 Allow up to 15 days for manufacturing |
PBCA610-220-24 $1102 Allow up to 15 days for manufacturing |
PBCA1000-110-24 $1357 Allow up to 15 days for manufacturing |
PBCA1000-220-24 $1357 Allow up to 15 days for manufacturing
|
PBCA1550-24 (replaces PBCA1503-110-24) $1957 Allow up to 15 days for manufacturing |
Country of Origin |
Canada, NAFTA eligible |
Canada, NAFTA eligible |
Canada, NAFTA eligible |
Canada, NAFTA eligible |
Canada, NAFTA eligible |
Canada, NAFTA eligible |
Canada, NAFTA eligible |
Nominal Input Voltage |
110VAC |
220VAC |
110VAC |
220VAC |
110VAC |
220VAC |
110VAC and 220VAC |
Input Voltage Range |
105-125 VAC |
210-250VAC |
90 - 130 VAC |
180 - 260VAC |
90 - 130 VAC |
180 - 260VAC |
90 - 140 VAC |
Absorption Stage Voltage |
28.8V |
28.8V |
28.8V |
28.8V |
28.8V |
28.8V |
28.8V |
Float Voltage |
27.2VDC |
27.2VDC |
27.2VDC |
27.2VDC |
27.2VDC |
27.2VDC |
27.2VDC |
Output Voltage Adjustment |
±1V typical |
±1V typical |
±1V typical |
±1V typical |
±1V typical |
±1V typical |
±1V typical |
Max Output Current(s) |
10 Amps |
10 Amps |
22 Amps |
22 Amps |
40 Amps |
40Amps |
50 Amps |
Transition current |
0.75 Amps |
0.75 Amps |
1.65 Amps |
1.65 Amps |
3
Amps |
3
Amps |
3.8 Amps |
Duty Cycle |
100% rated power 24 hours a day |
Reverse Polarity Protection? |
Yes |
Current Limiting? |
Yes |
Over Temperature shutdown? |
Yes |
Short Circuit Protection? |
Yes |
Stages |
2 or 3 user selectable |
Input Under voltage Shutdown? |
Yes |
Output Overvoltage Crowbar? |
Yes |
Output Crowbar Trigger |
63.9V ± 2V |
Dry Contact Output Fail
Relay? |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Can be left Permanently
Attached? |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Temperature Compensated
Charging? |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Temperature Compensation
Schedule |
-120 mV/°C |
-120 mV/°C |
-120 mV/°C |
-120 mV/°C |
-120 mV/°C |
-120 mV/°C |
-120 mV/°C |
Operating Temperature Range |
-25°C to +40°C |
-25°C to +40°C |
-25°C to +40°C |
-25°C to +40°C |
-25°C to +40°C |
-25°C to +40°C |
-25°C to +40°C |
Operating Temperature Range with
Derating |
-25°C to +50°C |
-25°C to +50°C |
-25°C to +50°C |
-25°C to +50°C |
-25°C to +50°C |
-25°C to +50°C |
-25°C to +50°C |
Derating |
2.5% per °C up to +50°C |
2.5% per °C up to +50°C |
2.5% per °C up to +50°C |
2.5% per °C up to +50°C |
2.5% per °C up to +50°C |
2.5% per °C up to +50°C |
2.5% per °C up to +50°C |
Efficiency |
>75 % |
>75 % |
>75 % |
>75 % |
>75 % |
>75 % |
>81% |
Line Regulation |
<±0.5% |
<±0.5% |
<±0.5% |
<±0.5% |
<±0.5% |
<±0.5% |
<±0.5% |
Load Regulation |
<±0.5% |
<±0.5% |
<±0.5% |
<±0.5% |
<±0.5% |
<±0.5% |
<±0.5% |
Transient Response |
<2V for 50% surge |
<2V for 50% surge |
<2V for 50% surge |
|
|
|
|
Switching frequency |
60 kHz |
60 kHz |
60 kHz |
|
|
|
|
Output ripple noise |
<25 mV rms |
<25 mV rms |
<50 mV rms |
<50 mV rms |
<50 mV rms |
<50 mV rms |
<50 mV rms |
Isolation |
>1500 volts isolation from case to any input terminal, >500V
isolation between case and any output terminal, >1500 Volts isolation input
to output. Transient voltage suppression. |
Indicators |
Audio and visual indicators for constant current, low input
voltage, low output voltage, over temperature. Dry Contact output failure
relay. |
Input Fuse |
5A MDA |
3A MDA |
10A MDA |
5A MDA |
25A MDA |
15A MDA |
25A Breaker |
Input Connection |
AC cord |
AC cord |
AC cord |
AC cord |
AC cord |
AC cord |
AC cord |
Connections |
4
contact screw terminal |
4
contact screw terminal |
4
contact screw terminal |
4
contact screw terminals |
4
contact screw terminals |
4
contact screw terminals |
Flying Leads |
Protection |
Over Voltage , Over Current, Short Circuit , Reverse Polarity ,
Over Load |
Dimensions |
244 x 208 x 64 mm (9.6 x
8.2 x 3.5 inches) |
244 x 208 x 64 mm (9.6 x
8.2 x 3.5 inches) |
368 x 251 x 76 mm (14.5
x 9.9 x 3 inches) |
368 x 251 x 76 mm (14.5
x 9.9 x 3 inches) |
368 x 251 x 140 mm (14.5
x 9.9 x 5.5 inches) |
368 x 251 x 140 mm (14.5
x 9.9 x 5.5 inches) |
411 x 212 x 100 mm
(16.16 x 8.4 x 4 inches) |
Drawings |
Click Here for Drawing |
Click Here for Drawing |
Click Here for Drawing |
Click Here for Drawing |
|
|
|
Weight |
3.4 Kg (7.5 lbs) |
3.4 Kg (7.5 lbs) |
3.3 Kg (7.2 lbs) |
3.3 Kg (7.2 lbs) |
5.5 Kg (12 lbs) |
5.5 Kg (12 lbs) |
14.4 lb ± 6.6 kg |
Audible Noise |
None |
None |
None |
3
years |
34.5 dB when fan is on |
34.5 dB when fan is on |
34.5 dB when fan is on |
Typical service life |
87000 hours |
87000 hours |
87000 hours |
87000 hours |
87000 hours |
87000 hours |
87000 hours |
Warranty |
3
years |
3
years |
3
years |
3
years |
3
years |
3
years |
3
years |
|
BCA310-110-24 |
BCA310-220-24 |
BCA610-110-24 |
BCA610-220-24 |
BCA1000-110-24 |
BCA1000-220-24 |
BCA1505-110-24 BCA1503-110-24 |
Approvals |
Built to meet UL458 and CSA 22.2.107.1 |