1200 watt
1 phase AC/AC phase converters |
1200VA frequency converter 110VAC 60 Hz
output
|
1200VA frequency converter 220VAC 60 Hz output
|
1200VA frequency converter 220VAC 50 Hz output
|
Part Number and
Price |
UFC1205-110 $3664
|
UFC1205-220N $3664 |
UFC1205-220W $3664 |
Input voltage |
90-264 VAC 50-60 Hz, single phase universal input |
90-264 VAC
50-60 Hz, single phase universal input |
90-264 VAC
50-60 Hz, single phase universal input |
Input amperage |
|
|
|
Output voltage |
110 VAC 60 Hz, 11 Amps single phase |
220 VAC 60
Hz, 5.5 Amps single phase |
220 VAC 50
Hz, 5.5 Amps single phase |
Output current |
10.5 Amps continuous |
5.45 Amps
continuous |
5.45 Amps
continuou |
EMI |
Meets EN55022 Class B (with margins) |
Meets EN55022
Class B (with margins) |
Meets EN55022
Class B (with margins) |
Operating temperature
range |
-0°C to +50°C with proper installation |
-0°C to
+50°C with proper installation |
-0°C to
+50°C with proper installation |
Humidity |
5-95% non-condensing |
5-95%
non-condensing |
5-95%
non-condensing |
Efficiency |
>80 % at full load |
>80 % at
full load |
>80 % at
full load |
Duty cycle |
Continuous power 24 hours per day |
Continuous
power 24 hours per day |
Continuous
power 24 hours per day |
Output wave form |
Pure sine wave, load crest factor 2 at 90% load |
Pure sine
wave, load crest factor 2 at 90% load |
Pure sine
wave, load crest factor 2 at 90% load |
Cooling |
Thermostatically controlled fan comes on when needed |
Thermostatically controlled fan comes on when needed |
Thermostatically controlled fan comes on when needed |
Over-temperature shut
down |
After prolonged operation at high ambient temperature the unit may
shut down by means of a thermal cutout switch. The unit will automatically come
back on when the chassis cools down, typically within 5 minutes. |
After
prolonged operation at high ambient temperature the unit may shut down by means
of a thermal cutout switch. The unit will automatically come back on when the
chassis cools down, typically within 5 minutes. |
After
prolonged operation at high ambient temperature the unit may shut down by means
of a thermal cutout switch. The unit will automatically come back on when the
chassis cools down, typically within 5 minutes. |
Input
connections |
|
|
|
Output connections |
|
|
|
Protection |
Current Limiting, Short Circuit , Spike and noise, over load, thermal shutdown
with automatic recovery |
Current
Limiting, Short Circuit , Spike and noise, over load, thermal shutdown with
automatic recovery |
Current
Limiting, Short Circuit , Spike and noise, over load, thermal shutdown with
automatic recovery |
Dimensions |
17 x 8.2 x 3.5 inches 43.2 x20.8 x 8.9 cm dimensions do not
include the carrying handle |
17 x 8.2 x
3.5 inches 43.2 x20.8 x 8.9 cm dimensions do not include the carrying
handle |
17 x 8.2 x
3.5 inches 43.2 x20.8 x 8.9 cm dimensions do not include the carrying
handle |
Weight |
14.4 lb, 6.6 kg |
14.4 lb, 6.6
kg |
14.4 lb, 6.6
kg |
Country of origin |
Made in Canada, NAFTA eligible |
|
|
Warranty* |
2 year *Warranty depends on installation within good engineering
practice. |
|
|