12V 5A battery chargers for lead acid, SLA, sealed lead acid,
Gel, AGM and VRLA batteries |
|
|
 |
|
PowerStream now offers a series of
fast chargers for sealed lead acid batteries specifically designed for the
personal electric vehicle market. They are based on switchmode technology,
which makes them more efficient and smaller than the old fashioned transformer
chargers, and are microprocessor controlled to make them very accurate.
| Quantity |
|
1-10 |
11-50 |
51-100 |
101-500 |
501+ |
PST-A100-12 with alligator
clips Includes USA 3 PIN power cord |
Precision multistage
charger For charging 12V Pb-Acid batteries at 5 amps |
$51.60
 |
$46.95 |
$39.80 |
$29.20 |
$25.80 |
|
PST-A100-12 12V Lead-Acid Battery charger |
|
|
ITEM |
UNIT |
SPECIFICATION |
REMARK |
| |
|
01 |
Rating Input Voltage |
V ac |
100~240Vac 50/60Hz |
|
|
02 |
Input voltage range |
V ac |
90~264Vac |
|
|
03 |
Rating Input Current |
A |
1.3Arms |
Measuered with:
INPUT:120V OUTPUT:Full load |
|
04 |
Max. input power |
W |
90 |
|
|
OUTPUT
|
|
05 |
Battery Charger Voltage Output |
V dc |
13.8V |
|
|
06 |
Output voltage range |
V dc |
10VDC ~ 15VDC |
|
|
07 |
Suit with Battery type |
|
12V 20~90Ah VRLA |
|
|
08 |
Battery charger current |
A |
5A±
0.4A |
This won't hurt your
battery no matter what the battery manufacturer says is the maximum charge
current, since this is a sophisticated, tightly regulated, multistage
charger |
|
09 |
Bulk Charging voltage Limit |
V |
14.8V+-0.1V |
|
|
10 |
Floating charge voltage
limit |
V |
13.8V+-0.1V |
|
|
11 |
Charge End condition |
|
I < 0.8A |
|
|
12 |
Desulphate recovery
current |
A |
-
|
Not including
|
|
13 |
Max. output power |
W |
75W |
|
|
14 |
Typical charging time
|
hours |
8~10 hours
|
For 22Ah VRLA battery. |
|
15 |
Ripple current |
mA |
300 |
Input: 230Vac Output: Full load
|
|
16 |
Charge Mode |
|
Auto 3 stages |
|
|
17 |
LED indicator |
|
Red: charging
Green: finished/idle
|
See User Manual
|
|
18 |
Output
Shorted protect
Output Reversed
protect |
-
|
YES
YES |
|
|
19 |
Efficiency |
%
|
83% |
At max. load
|
|
Environment
|
|
20 |
Operating temperature |
°C |
-10 ~ +40 |
Full load & natural convection.
|
|
21 |
Operating humidity |
%RH |
< +90 |
Relative humidity, non-condensing.
|
|
22 |
Storage temperature |
°C |
-40 ~ +70 |
|
|
23 |
Storage humidity |
%RH |
0 ~ +95 |
Relative humidity, non-condensing.
|
|
24 |
Cooling |
-
|
Natural convection |
|
|
25 |
Impact |
|
1 meter drop test
>= 3 times |
Non-operating condition.
|
|
Mechanical
|
|
26 |
Weight |
g |
650 |
|
|
27 |
Size |
mm |
190X100X60 |
Casing only |
|
28 |
Input/Output Cord &Terminals
|
|
Input cord is an IEC-C14 C15 removable cord Output is
Alligator clips |
|
|
Safety
|
|
29 |
Max. temperature rise |
°C |
< 40 on casing |
At any line and Max. Load
|
|
30 |
Safety standards |
-
|
EN60335 UL1310 |
|
|
31
|
EMC standard |
-
|
T.B.D. |
|
|
32
|
MTBF |
hrs |
30000 |
|
|
33
|
ESD |
kV
|
8.0 |
|
|
34 |
Hi-Pot Insulation |
V |
i/p to o/p: 3000 (1 min.)
|
For
final unit, cut-off current =10mA |
Advantages:
Fast Charge
Algorithms
Switching power supplies
make chargers portable
Universal Power Input
No NRE
required
Samples available now
|
|
|
|
|
|
PowerStream Technology: 140 South Mountainway Drive, Orem Utah 84058
Phone: 801-764-9060
Fax: 801-764-9061
|
| |
|
|
|
|
© Copyright 2000,
2001, 2002, 2003, 2004, 2005, 2006, 2007, 2009 Lund Instrument Engineering,
Inc. All rights reserved This material is copyrighted original work.
It is forbidden to use this information, text, or graphics in full or in part
on another web site without written permission. |
Storage battery charger 5 amps, switchmode variety |
|
|